E.coli cfu per 100mL
What's this?
0.0
East Spillway : Pearl River
Brandon, Mississippi, United States
Observed by
LeAnn Nealey
- Observed on: Wed, 12 Jul 2023 14:10:00 -0500
- Testers Luke & LeAnn Nealey
-
Associated with:
Mississippi State University : Mississippi Water Stewards - Lat: 32.3944936
- Lng: -90.0654244
Observation report
See trends at this locationWater quality tests
✓ Quality checked by Water Rangers What's this?
Other coliform cfu per 100mL
What's this?
1,133.33
Total coliform cfu per 100mL
What's this?
1,133.33
Air temperature °C
What's this?
33.0
Incubation time (hours)
What's this?
24.0
Water temperature °C
What's this?
29.5
Incubation temperature °C
What's this?
37.0
Microplastics
Weather
Current weather What's this?
Weather in previous 24 hours What's this?
Latest photos
Notes
Hot, still. Water average height, water brown but fairly clear (very little sediment)