E.coli cfu per 100mL
What's this?
233.33
Westbrook Rd : Pearl River
Brandon, Mississippi, United States
Observed by
Will McDearman
- Observed on: Wed, 01 Sep 2021 16:40:00 -0500
- Testers Will McDearman
-
Associated with:
Mississippi State University : Mississippi Water Stewards - Lat: 32.3650645
- Lng: -90.1007438
Observation report
See trends at this locationWater quality tests
✓ Quality checked by Water Rangers What's this?
River stage feet
What's this?
18.4
Other coliform cfu per 100mL
What's this?
2,466.67
Total coliform cfu per 100mL
What's this?
2,700.0
Air temperature °C
What's this?
34.0
Incubation time (hours)
What's this?
40.0
Water temperature °C
What's this?
30.0
Incubation temperature °C
What's this?
34.0
Microplastics
Weather
Current weather What's this?
Weather in previous 24 hours What's this?
Latest photos
Notes
River stage at downstream Hwy 25 Lakeland Drive gauge. River at very low flow due to low summer discharge from upstream reservoir spillway. Very little current. Monitoring form not used or uploaded because home printer broken.