River Wey near Plough Bridge, Byfleet : River Wey

Byfleet, Surrey, United Kingdom

Observed by
Susan Clements
pH (0-14) What's this? 6.8
E.coli cfu per 100mL What's this? 5,667.0
Chlorine ppm What's this? 0.0
Hardness mg/L What's this? 200.0
Nitrates mg/L What's this? 7.5
Alkalinity mg/L What's this? 120.0
Conductivity μS/cm What's this? 478.0
Air temperature °C What's this? 7.0
Water temperature °C What's this? 8.3
Phosphates total ppm What's this? 0.02

Weather

Current weather What's this?
  • cloudy
Weather in previous 24 hours What's this?
  • cloudy

Latest photos

No photos uploaded.


Notes

Water level and flow average. Water brown and opaque with no odour or foam. E. coli tested using the R cards (first attempt at this method). Colony numbers on the three cards were 43, 57 and 70 (quite variable), giving a final value of 5667 CFU/100 ml, which is higher than normal. Unfortunately I couldn’t compare directly with IDEXX this time as the lab was closed for Christmas.