Center Deep Spot

Loon Lake

Ontario, Canada

Location created by
Mike Grinnell

Latest photos

View all photos

Testing of home made Nephelometer using Arduino platform and Keystudio turbidity sensor complete with digital/analog amplifier gave a voltage output of 4.15vdc that equated to an NTU OF 156. Based on a linear relationship between voltage and NTU. Since the NTU is excessive, a manufacture’s quadratic equation will be evaluated. Should have 4.2v producing 0 NTU.

05 May 13:30 by Mike Grinnell

Ammonia/Ammonium 0.25 ppm; Hydrogen Sulphide 0.0 ppm
This is the final water sampling/testing until ice out 2022.

06 Oct 14:00 by Mike Grinnell

H2S = 0 ppm using low range lead acetate test strips.
Ammonia and ammonium = <2.5 ppm

13 Sep 10:30 by Mike Grinnell

Ammonia and Ammonium 0 ppm
TDS 70 ppm

15 Aug 13:30 by Mike Grinnell

Ammonia/Ammonium = 0 ppm.
Colour of white sectors of Secchi disk were amber/orange. This at 4.25 meters.
This is a change - usual is more white sector.

02 Aug 10:30 by Mike Grinnell

Test strips used for Ca hardness, total alkalinity, pH, total hardness, nitrite, nitrate, therefore readings not exact.

13 Jun 11:30 by Mike Grinnell

The DO test was done under full ice cover using a borrowed MOECP meter.
Some information (above) is from MOECP 2019 sampling as part of the Lake
Partner Program.
This is a snapshot of the lake. It remains relatively constant.
There is a slight yr/yr increase in chlorides because of the proximity of Hwy 118E with
winter salting.

17 May 18:15 by Mike Grinnell